A vibration test system is more than a shaker and an amplifier. Whether control will run cleanly is decided during set-up: foundation, coupling to the building, slip table, head expander, fixture and measurement chain together form one dynamic system. If one of these resonances lies in the test range, the controller fights against it – with aborts, overtesting and wrongly loaded specimens.
How we work
- Define requirements – standards, specimens, masses, profiles and future needs
- Size the system – force, stroke and velocity from sine, random and shock profiles; slip table, cooling, climatic chamber
- Plan the installation – foundation or seismic block, isolation from the building (DIN 4150, VDI 2062), space and utilities
- Design fixtures – head expanders and adapters by FEM, first natural frequency above the test range
- Measurement chain and control – transducers and mounting (ISO 5348), cable routing, control strategy and abort limits
- Commissioning and acceptance – transfer functions, cross-axis motion, bare-table and loaded profiles, documentation and training of your team
New purchase
For new systems we recommend electrodynamic vibration test systems from our partner RMS Dynamic Test Systems in Reinbek, Germany. We coordinate the sizing with you and the manufacturer and accompany delivery, installation and acceptance. We optimise existing systems from other manufacturers just the same.
For a first estimate of which system fits your test profiles, use our shaker sizing tool. Below you can try how the tuning of the mounting changes the transmission into the building.
How an elastic mount works
- Transmissibility T
- –
- Effect
- –