Shock testing via a required shock response spectrum (SRS) instead of a fixed pulse shape.
Typical parameters
- Requirement
- Shock response spectrum (SRS)
- Signal
- synthesised
Requirements
- Requirement
- Required shock response spectrum over frequency, mostly for 5 % damping (Q = 10)
- Signal
- Synthesised time signals, e.g. from decaying sinusoids (wavelets)
- Tolerance
- The achieved spectrum has to lie within the specified limits around the required one
- Number
- Number of shocks and directions as specified
- Application
- Complex shock loads, pyroshock substitute, replicating measured events
Summary of the key specifications in our own words, without guarantee. The current edition of the standard and your test specification are binding; many values are given there as a choice or as preferred values.