ISO 5348

Mechanical vibration and shock – Mechanical mounting of accelerometers

Calibration

How the mounting of an accelerometer determines its usable frequency range.

Requirements

Objective
The mounting must not distort the frequency response and the measurement
Mounting (from stiff to soft)
Stud on a flat machined surface with coupling fluid, adhesive, wax or adhesive pad, magnet, hand-held probe
Effect
The softer the mounting, the lower the mounted resonance and thus the upper frequency limit
Mass
Keep the transducer mass small compared with the measuring point (mass loading)
Cable
Fix the cable close to the transducer to avoid cable whip and spurious signals

Summary of the key specifications in our own words, without guarantee. The current edition of the standard and your test specification are binding; many values are given there as a choice or as preferred values.