Mandatory tests for transporting lithium batteries, including T3 vibration and T4 shock.
Typical parameters
- T3
- Sine 7–200 Hz, 3 h per axis
- T4
- Half-sine 150 g / 6 ms or 50 g / 11 ms
Requirements
- Sequence
- T1 to T5 in sequence on the same samples
- Criteria
- No leakage, venting, disassembly, rupture or fire; open-circuit voltage at least 90 % of the initial value
T3 vibration
- Signal
- Sine, logarithmic sweep 7 → 200 → 7 Hz in 15 min, 12 cycles = 3 h per axis, three axes
- Level
- 7–18 Hz 1 gn; then 1.6 mm peak-to-peak up to about 50 Hz; 50–200 Hz 8 gn (large batteries above 12 kg: max. 2 gn)
T4 shock
- Pulse
- Half-sine 150 gn / 6 ms for small cells and batteries, 50 gn / 11 ms for large ones
- Number
- 3 shocks per direction, 18 in total
Summary of the key specifications in our own words, without guarantee. The current edition of the standard and your test specification are binding; many values are given there as a choice or as preferred values.